1. Question
1 pointsThe individual modular boiler shall be limited to a maximum input rating of ______ Btulh gas:
Correct
Please Refer: IMC Code – Definitions
Incorrect
Please Refer: IMC Code – Definitions
-
Question 2 of 8
2. Question
1 pointsFor determining all welded and brazed joints are liquid tight, a light test shall be performed by passing a lamp having a power rating not less than _____ through the entire section of duct work to be tested.
Correct
Please Refer: IMC Code 506.3.2.5
Incorrect
Please Refer: IMC Code 506.3.2.5
-
Question 3 of 8
3. Question
1 pointsExhaust Openings in screens, louvers and grilles terminating at outdoor shall be sized not less than ______ :
Correct
Please Refer: IMC Code 501.3.2
Incorrect
Please Refer: IMC Code 501.3.2
-
Question 4 of 8
4. Question
1 pointsFor flooded lead acid, flooded nickel cadmium and VRLA batteries, the ventilation system shall be designed to limit the maximum concentration of hydrogen to _____ of the total volume of the room
Correct
Please Refer: IMC Code 502.4.1
Incorrect
Please Refer: IMC Code 502.4.1
-
Question 5 of 8
5. Question
1 pointsSmoke dampers are not required in corridor penetrations where the duct is constructed of steel not less than _____ in thickness and there are no openings serving the corridor:
Correct
Please Refer: IMC Code 607.5.4 Exp 3
Incorrect
Please Refer: IMC Code 607.5.4 Exp 3
-
Question 6 of 8
6. Question
1 pointsWhere ducts used for cooling are externally insulated, the insulation shall be covered with a vapor retarder having a maximum permeance of ______ perm:
Correct
Please Refer: IMC Code 604.11
Incorrect
Please Refer: IMC Code 604.11
-
Question 7 of 8
7. Question
1 pointsOil-burning appliances listed and labeled for venting with _______ vents:
Correct
Please Refer: IMC Code Table 802.2
Incorrect
Please Refer: IMC Code Table 802.2
-
Question 8 of 8
8. Question
1 pointsChimney connectors for low-heat appliances shall be of sheet steel pipe having diameter of 7 inches shall have minimum normal thickness of _____ that of galvanized steel:
Correct
Please Refer: IMC Code Table 803.9(1)
Incorrect
Please Refer: IMC Code Table 803.9(1)