International Mechanical Code (IMC) Practice Test
You have already completed the quiz before. Hence you can not start it again.
Quiz is loading...
You must sign in or sign up to start the quiz.
You have to finish following quiz, to start this quiz:
Results
0 of 8 questions answered correctly
Your time:
Time has elapsed
You have reached 0 of 0 points, (0)
Average score |
|
Your score |
|
Categories
- Not categorized 0%
- 1
- 2
- 3
- 4
- 5
- 6
- 7
- 8
- Answered
- Review
-
Question 1 of 8
1. Question
1 pointsLiquids having flash points at or above 100°F (38°C) and below 140°F (60°C) comes under ________ combustible liquid:
Correct
Incorrect
-
Question 2 of 8
2. Question
1 pointsUnderground commercial kitchen grease duct installation shall be completely encased in concrete with a minimum thickness of _____ inches:
Correct
Please Refer: IMC Code 506.3.10.3
Incorrect
Please Refer: IMC Code 506.3.10.3
-
Question 3 of 8
3. Question
1 pointsMechanical and gravity outdoor air intake openings shall be located not less than _____ horizontally from any hazardous or noxious contaminant source
Correct
Please Refer: IMC Code 401.4.2
Incorrect
Please Refer: IMC Code 401.4.2
-
Question 4 of 8
4. Question
1 pointsCommercial kitchen Grease duct systems serving a Type I hood shall be designed and installed to provide an air velocity within the duct system of not less than ______ feet per minute:
Correct
Please Refer: IMC Code 506.3.4
Incorrect
Please Refer: IMC Code 506.3.4
-
Question 5 of 8
5. Question
1 pointsLiquid adhesive coatings used on air filters for air conditioning or heating systems shall have a flash point not lower than _______ :
Correct
Please Refer: IMC Code 605.1
Incorrect
Please Refer: IMC Code 605.1
-
Question 6 of 8
6. Question
1 pointsWhere a damper is installed within a duct, a smoke detector shall be installed in the duct within _____ of the damper with no air outlets or inlets between the detector and the damper:
Correct
Please Refer: IMC Code 607.5.4.1.1
Incorrect
Please Refer: IMC Code 607.5.4.1.1
-
Question 7 of 8
7. Question
1 pointsWhere located adjacent to walkways, the vertical termination of mechanical draft systems shall be not less than ______ above the level of the walkway:
Correct
Please Refer: IMC Code 804.3.5.1
Incorrect
Please Refer: IMC Code 804.3.5.1
-
Question 8 of 8
8. Question
1 pointsConnectors shall connect to a chimney flue at a point not less than ______ above the lowest portion of the interior of the chimney flue:
Correct
Please Refer: IMC Code 801.12
Incorrect
Please Refer: IMC Code 801.12